ACTION INTHEEVENTOFA FIREHAZARD

A fuelling operation shall be suspended and theAirport FireServicenotified

when any fuel of a quantity likely to create a firehazard is spilledon orwithin

15metres (50 feet) of the aircraft or ground fuelling equipment, including the

bilge of a fuellingbarge, and theoperation shall not recommenceuntil the fire

hazard is removed.

A fuelling operation shall be stopped as soon as it becomes apparent that

an infringement exists of any of the relevant requirements of CAO 20.9.

When any fuel of a quantity likely to create a firehazard is spilled onorwithin

15metres (50 ft) of the aircraft or ground fuelling equipment, the pilot in

command or, in his absence, theoperator shall ensure that:

• mobilepower units, vehicles and power operated loadingdevices

operatingwithin 15metres (50 ft) of the spilled fuel are shut down; and

• maintenancework of any nature on orwithin the aircraft is suspended and

not recommenced until the spilled fuel has been removed.

STARTINGANDRUNNINGOFENGINES (CAR230)

A personmust not:

• start the engine of an aircraft; or

• permit the engine of an aircraft to be run;

except that:

the enginemay be started or run if the control seat is occupied by an

approvedperson or by a personwhomay, under CARPart 5 (flight crew

licencing), fly the aircraft; or if the aircraft is an aeroplane that is having

maintenance carriedout on it, or that is being used for theprovisionof

maintenance training, the enginemay be startedor run if the control seat is

occupied by a personwho:

• holds an aircraftmaintenanceengineer licence, or an airworthiness

authority, coveringmaintenance of the aircraft’s engine; and

refuelling

engine ground operation

1 — P I LOT RESPONS I B I L I T I ES